CHAPTER 2 SETUP AND OPERATION
2-9
WHERE TO GO FROM HERE
If you w ant to do th is Go to
chapter
Save a program 3
Autorun a program 3
Know m ore abo ut serial por ts 4
Use the SPI port 4
Using RAM to save variables 5
Storing variables in F lash 5
Configure digital I/O lines 6
Read switch status 6
Use high current outputs 6
Connect an external opto rack 6
Using calendar/clock 7
Reading voltages (Analog input) 8
Analog output 8
Using a keypad 9
Character display port 10
Sound or timer output 11
Using inter rupts 13
Using high speed counter 14
Graphics display 15
Power input and output 16
Expansion port 16
Also, refer to the table of contents for a listing of major
functions.
TROUBLESHOOTING
You probably turned to this section because you could
not get the sign on message. The following are
troubleshooting hints:
1. Check the power on the RPC-2350. A good place is
C13+ and -. If it is below 4.65 volts, the RPC-
2350 will be r eset. Power is 5 ±0.25 volts. If it
dips intermittently to 4.65 volts (due to switching
noise or ripple), the card will reset for about 100
ms. If the noise is frequent enough, the card will be
in permanent reset. Check U14, pin 6. If it is low
(about 0 volts), then it is in reset. This line should
be high (about + 5 volts).
If you are using a 6-15V supply, make sure it does
not dip below 6V even intermittently. Use a scope
to make sure it does not. A voltmeter m ay not be
good enough.
The same can be said for the 5V supply. Make sure
it does not dip below 4.8V using an oscilloscope.
2. Check the COM1 port. COM 1 is also known as
console port J1. Remove the connector from
COM 1. Refer to the outline drawing ear lier in this
chapter. Connect an oscilloscope (preferred) or a
voltmeter to pin 3 (Txd ) and gro und. Pin 3 should
be -6 volts or more negative. (Pin 1 is designated
by the ^ sym bol on the connector. Pin 3 is next to
it, nearer the key opening.) If you have -6 volts or
more, press the reset switch. If you have a scope
attached, you should see a burst of activity. If you
have a volt meter, you should see a change in
voltage. Using a Fluke 8060A set to measure AC,
you should see a mom entary rea ding above 2 volts.
Press reset several times to make sure it captu res it.
3. Install the cable and make sure the voltages and
output activity are still there. Output is from pin 3
on the VTC-9. Check to make sure something is
not shorting the output.
4. Check the serial pa ram eters on your P C or terminal.
They should be set to:
19200 baud, no parity, 8 data bits, 1 stop
If all of this fails, call technical support listed at the front
of the book.