Remote-processing CAMBASIC Manuel d'utilisateur Page 134

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 208
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 133
Commands - 101
PULSE
Process Function
SYNTAX: n= PULSE(m)
PURPOSE: To return the r emaining time of a pulsed output.
REMARK S: The resolution of the software pulse timers is 0.005 seconds (0.01 sec in 9 Mhz systems). The
remaining time is returned in seconds. A time of 0 indicates the PULSE comm and finished.
The argument range for m is 0 to 7, which is the pulse number set by the PULSE command.
See the Multitasking Chapter for more information.
RELATED: CLEAR PU LSE, PULSE command
EXAMPLE: 10 A=PULSE(2)
ERROR: < Data negative> for m
< Illegal argument> if m > 7
Vue de la page 133
1 2 ... 129 130 131 132 133 134 135 136 137 138 139 ... 207 208

Commentaires sur ces manuels

Pas de commentaire