CALENDAR/CLOCK SECTION 7
Page 7-1 RPC-330
DESCRIPTION
An optional DS1216DM calendar/clock module may be
installed in U5. The DS1216DM also battery backs
RAM.
The DS1216DM from Remote Processing is a modified
version of the Dallas DS1216D. An internal reset line
has been cut. When a 512K RAM is installed, an
additional line must be cut. Contact Remote Processing
for details.
Battery life depends greatly upon the ambient
temperature. Battery life degrades up to 50% at 50°C,
using 25°C as a reference. RAM size and type also
affect battery life. Generally, you can expect a battery
life of 3 to 5 years.
Accuracy is about 1 minute/month and is not adjustable.
Hours are expressed in 24-hour fo rma t.
Refer to the RPBASIC-52 Software Supplement for
more command information.
The clock module is installed by first r emoving the IC in
U5. Then, install the DS1216DM into the socket. Install
the RAM chip into the socket. When installing a 32K
RAM chip, the top two pins in the DS1216DM are left
open.
Refer to SECTION 5 for information about using battery
backed RAM and jumper setting when installing a 512K
RAM.
WARNING: An additional modification to the
DS1216DM is necessary when
installing a 512K RAM. Contact
Remote Processing for details.
SETTING DATE AND TIME
Set the date to turn on the clock module. Date and time
are set while running a progr am or in the immediate
mode. Date and time are treated as number s and not
strings. To set the date and time:
DATE 97,02,10
TIME 13,23,43
Date is February 10, 1997. The time is set to 1:23:43
PM.
NOTE: The clock module is turned off as shipped from
the factory. DATE and TIME functions return
a HARDW ARE error until DA TE is set first.
To retrieve date and time as part of a program:
100 PRINT "Time: ",
110 FOR N=0 TO 2
120 PRINT TIME(N),
130 NEXT
140 PRINT "Date: ",
150 FOR N=0 TO 2
160 PRINT DATE(N),
170 NEXT
180 PRINT CR,
190 GOTO 100
run
Time: 13 24 12 Date: 97 2 10
When the clock module is missing, defective, or the date
has not been set, a HARD WARE er ror (code 50 at
address 101H) is returned by RPBASIC when a DATE
or TIME function is performed. Use ONE RR to trap for
this error and report the problem.
COMMANDS
The following is a list of RPBASIC-52 commands for
the calendar/clock.
Command Function
DATE Sets date and tur ns on module
DATE(n) Returns date
TIME Sets time
TIME(n) Returns time