ANALOG INPUT SECTION 10
Page 10-5 RPC-330
Figure 10-2 Amplifier Circuit
AMPLIFIERS
Two operational amplifiers are available to signal
condition inputs.
Amplifiers are accessed through header connector H1.
Pin out is as follows:
H1 pin Function
1 Temperature output from U14
2 To channel 0 analog input
3 Non-inverting input, amplifier A
4 Output from amplifier A
5 Inverting input, amplifier A
6 Appr oximately + 12V supply
7 Ground
8 Ground
9 Non-inverting input, amplifier B
10 Approximately -12V supply
11 Inverting input, amplifier A
12 Output from amplifier A
13 5.000 V r eference output
14 Ground
Voltage outputs from pins 6 and 10 are generated by the
RS-232 chip U8. These voltages go to 0 volts when
operating the board in IDLE m odes 1 or 2.
CALIBRATION
The A/D comes factory calibrated for a 0 to 5V input.
This range is changed by adjusting R17. You can adjust
the range to 5.12V. This is useful when the input is 0 -
5V and you want to know when the input is over-range.
To calibrate or adjust the voltage reference:
1. Connect the voltmeter ground to a GND point
on the Analog IN terminal strip. Make sure
there are no other connections to the analog
ground.
2. Connect the voltmeter ' + ' lead to U14, pin 6.
3. Adjust R5 for 5.00 VDC or other voltage as
desired. Do not exceed 5.2 or go below 4. 8
volts.
COMMANDS
The following RPBASIC-52 com mands are used for
analog input. More inform ation is found in the appendix
of this manual.
Command Function
AIN(n) Returns analog value.
CONFIG AIN (n) Configures analog input
channels